Compatible OBIS codes

OBIS code compatibility list with OneMeter device.

Processing policy

Here you have a list of the codes processed by the device from the last reading, advertised and stored in memory. If the last readout failed or it was not yet available (after restarting the device), the device provided mainly special codes from the last reading. Data from previous readings stored in memory will still be available for synchronization.

Note: The legend is under the table (or available by clicking / hovering over). We recommend that you use a monitor to read this section.

OBIS code last reading advertised stored
0.0.0
0.2.2
0.9.1
0.9.2
0.9.4
1.2.1
1.4.0
1.5.0
1.6.0
1.6.1
1.6.2
1.6.3
1.6.4
1.8.0
1.8.1 N_0 N_0
1.8.2 N_0 N_0
1.8.3 N_0 N_0
1.8.4 N_0 N_0
2.8.0 N_0 N_0
2.8.1 N_0 N_0
2.8.2 N_0 N_0
2.8.3 N_0 N_0
2.8.4 N_0 N_0
3.8.0 N_0 N_0
3.8.1
3.8.2
3.8.3
3.8.4
4.8.0 N_0 N_0
4.8.1
4.8.2
4.8.3
4.8.4
5.8.0 N_0 N_0
5.8.1
5.8.2
5.8.3
5.8.4
6.8.0 N_0 N_0
6.8.1
6.8.2
6.8.3
6.8.4
7.8.0 N_0 N_0
7.8.1
7.8.2
7.8.3
7.8.4
8.8.0 N_0 N_0
8.8.1
8.8.2
8.8.3
8.8.4
15.6.0
15.6.1
15.6.2
15.6.3
15.6.4
15.7.0
15.8.0 / F.8.0 N_1 N_1
15.8.1 / F.8.1 N_2 N_2
15.8.2 / F.8.2 N_2 N_2
15.8.3 / F.8.3 N_2 N_2
15.8.4 / F.8.4 N_2 N_2
C.1.0
C.90.1
F.F.0
S.1.1.2
S.1.1.4
S.1.1.6
S.1.1.7
S.1.1.8
S.1.1.9
S.1.1.10
S.1.1.12
S.1.1.16

S.1.1.12 code exists in case of readout from control output.

Data storage

The device can preserve up to 16 OBIS codes (for latter synchronization) by descending priority:

  • 1.8.0 or 15.8.0
  • 2.8.0
  • 3.8.0, 4.8.0, 5.8.0, 6.8.0, 7.8.0, 8.8.0
  • 1.8.1, 1.8.2, 1.8.3, 1.8.4,
  • 2.8.1, 2.8.2, 2.8.3, 2.8.4
OBIS code last reading advertised stored
0.0.0
0.2.2
0.9.1
0.9.2
0.9.4
1.2.1
1.4.0
1.5.0
1.6.0
1.6.1
1.6.2
1.6.3
1.6.4
1.8.0 N_0 N_0
1.8.1 N_0 N_0
1.8.2 N_0 N_0
1.8.3 N_3 N_3
1.8.4 N_3 N_3
2.8.0 N_0 N_0
2.8.1 N_0
2.8.2 N_0
2.8.3 N_0
2.8.4 N_0
3.8.0 N_0 N_0
3.8.1
3.8.2
3.8.3
3.8.4
4.8.0 N_0 N_0
4.8.1
4.8.2
4.8.3
4.8.4
5.8.0 N_0 N_0
5.8.1
5.8.2
5.8.3
5.8.4
6.8.0 N_0 N_0
6.8.1
6.8.2
6.8.3
6.8.4
7.8.0 N_0 N_0
7.8.1
7.8.2
7.8.3
7.8.4
8.8.0 N_0 N_0
8.8.1
8.8.2
8.8.3
8.8.4
15.6.0
15.6.1
15.6.2
15.6.3
15.6.4
15.7.0
15.8.0 N_2 N_2
15.8.1 N_4
15.8.2 N_4
15.8.3 N_4
15.8.4 N_4
F.8.0 N_2 N_2
F.8.1
F.8.2
F.8.3
F.8.4
C.1.0
C.90.1
F.F.0
S.1.1.2
S.1.1.4
S.1.1.6
S.1.1.7
S.1.1.8
S.1.1.9
S.1.1.10
S.1.1.12
S.1.1.16

S.1.1.12 code exists in case of readout from control output.

Data storage

The device can preserve up to 16 OBIS codes (for latter synchronization)

Legend

N_0 - ✅ if the value is non-zero

N_1 - ✅ if 1.8.0 does not exist

N_2 - ✅ if the value is non-zero and 1.8.0 does not exist

N_3 - ✅ if the value is non-zero and at least 2 tariff codes are non-zero

N_4 - ✅ if the value is non-zero, 1.8.0 does not exist and at least 2 tariff codes are non-zero


🠕 Processing policy · 📁 OBIS codes index · 🔄 Synchronization mode


Poslední aktualizace: 2023-02-14